SR Series
Thermostatic reagent cabinet
1 DoorPatent no. 10-1083260(Thermostatic reagent safety cabinet)
Purpose of use
Technical Specifications
scroll left and right >
※ Specification are subject to change without notice for improved performance
Standard / Model | ZEO-SR354 | ZEO-SR154 |
---|---|---|
External Size(WxDxH)mm | 970 x 800 x 1,800 | 970 x 800 x 1,800 |
Interior Size(WxDxH)mm | 560 x 538 x 1,660 / 500 L | 560 x 538 x 1,660 / 500 L |
Max, load per shelf | 30 Kg | 30 Kg |
Noise Level | Below 55 dB | Below 55 dB |
Shelves | 5 Slide unit | 5 Slide unit |
Shelves (Materials) | SUS304 | SUS304 |
Unit Weight | 265 kg | 265 kg |
Power Consumption | 600 W (1,560 W) | 600 W |
Lock System | Electronic Lock | Electronic Lock |
Compressor | 1/3 HP | 1/4 HP |
Internal Heater | 1 KW | - |
Temp. Range | 2 °C ~ 25 °C(±2 °C) | 4°C ~ 15 °C(±2 °C) |
Option | - |
Features
Fully-enclosed / self-circulating structure prevents air leakage from the inside of the reagent cabinet
- A contaminated air flowing into the reagent cabinet, over-saturate the filter and reduce filter life.
- A contaminated filters can be a source of pollution, emitting odor and harmful gas.
- A self-circulation avoid loss of cooling and heating energy
Fluid dynamics design Creation of ideal filter efficiency via pressure diffrential pressure
- The reagent cabinet is designed ti have negatice pressure of-0.3 hpa by differential pressure
- The air inside the cabinet is not vented to the outside
- The flow of velocity at the bottom of cabinet is designed to be 0.5 m/s to prevent the back-flow of odor and harmful gas molecule
KASSIA module (Ion-cluster)
Removes odor and harmful gas with ion cluster Ion cluster is a group of 10~60 oxygen molecules that directly oxidize various radicals including oxygen anions, cations and OH and odor substance eliminate pollutants.
- The KASSIA module equipped with semi-permanent ion cluster removes odor and harmful gas.
- Removes over 95 % of odor and harmful gas.
CxHy + (x+y/4)O2
xCO2 + (y/2)H2O
scroll left and right >
NAME | Chemical formula | Elimination reaction | |
---|---|---|---|
Toluene | C₇H₈ |
C₇H₈ + 9O₂
CO₂ + H₂O
|
|
Benzene | C₆H₆ |
2C₆H₆ + 15O₂
12CO₂ + 6H₂O
|
|
Methane | CH₄ |
CH₄ + 2O₂
CO₂ + 4H₂O
|
|
Ammonia | NH₃ |
4NH₃ + 3O₂
2N₂ + 6H₂O
|
|
Acetaldehyde | C₂H₄O |
2C₂H₄O + 5O₂
4CO₂ + 4H₂O
|
|
Formaldehyde | CH₂O |
CH₂ + O₂
CO₂ + H₂O
|
|
Ethylene | C₂H₄ |
C₂H₄ + 3O₂
2CO₂ + 2H₂O
|
7-inch color touch display
- Temperature, humidity, VOCs concentration display
- gas concentration and humidity live graph display
- Display of KASSIA Module and filter inspection interval graph (notification)
Materials
- 1.2 mm cold rolled steel plate + powder coating (Polypropylene)
MSlide-out Shelvesaterials
- Various reagent can be stored with height adjustable shelves
- Convenient reagent storage with sliding shelves
- Shelves are secured by using a latch method to prevent reagent waste container from falling
- The waste reagent container is secured with a latch method
- Material SUS304