ZEO-K20C
Hazardous gas removal device (Standing-type)
Patent No. 10-0959634 (Hazardous gas purification and removal devices)
Purpose of use
Technical Specifications
Standard / Model | ZEO-K20C |
---|---|
External size (WxDxH)mm | 575 x 600 x 1,800 mm |
Area of use | 50 ~ 80 m³ |
Power consumption | 220 V / 60 Hz, 170 W |
Weight | 90 kg |
Display | 7-inch LCD |
operation method | Touch screen |
Fan speed (automatic) | 1-9 Level operation |
concentration display | Fine dust / Gas |
Air purification | Fine dust - HEPA filter Harmful gas - KASSIA Module(Semi-permanent used) Harmful gas - Chemical Filter Anti-microbial pre-filter - Demister *he Chemical Filter is a dedicated filter that removes organic solvents, alkali acids, ammonia, formaldehyde, etc., and can be used for the desired purpose |
Time setting | O |
Sensor | Dust / Gas / Humidity |
Features
KASSIA Moduel
- Removes odor and harmful gas
- No ozone generation
Centrifugal Fan
- Low energy consumption and high performance
Filter
- Exclusive filter for odor and VOCs (option)
FAN CONTROL
- If fan speed is set to automatic, fan speed will be automatically controlled according to the gas concentration (level 1-9)
Laser dust sensor
- Detect every dust molecules(0.3 um) and indicates concentration live
IAQ gas sensor
- As a system-on-chip, it includes an embedded microcontroller with an AMS algorithm that detects volatile organic compounds in an indoor environment with low power consumption and converts the detected results into measurements.
Filter
Demister filter
- Filter that removes more than 60 % of dust
- STS 304 material used for semi-permanent use
- Reusable without filter replacement
Chemical filter
- High-performance catalysts, adsorbents and chemical filters
- Optimize of physical adsorption by controlling the size and distribution of micro-pores
- Maximize chemical adsorption through surface modification and functional group attachment
- Exclusive filter for various VOCs and odor
KASSIA module
- Odor and harmful gas removal
- Semi-permanent use
HEPA filter
- Depending on the air volume. various filters can be selected (99.9 % Collected at 0.3 μm)