Acid resistance reagent cabinet (strong acid and alkali)
SNP series
Fully-enclosed·Self-circulating
2 Door
Fully-enclosed·Self-circulating
Acid resistance reagent cabinet
2 Door
Patent no. 10-0776563(Fully-enclosed·Self-circulating reagent safety cabinet)
CE certified product
Purpose of use
Technical Specifications
scroll left and right >
※ Specification are subject to change without notice for improved performance
Standard / Model | ZEO-SN142P | ZEO-SN152P |
---|---|---|
External Size(WxDxH)mm | 970 x 565 x 1,800 | 970 x 565 x 1,800 |
Interior Size(WxDxH)mm | (600 x 450 x 775) x 2 EA / 420 L | (600 x 450 x 775) x 2 EA / 420 L |
Max, load per shelf | 30 Kg | 30 Kg |
Noise Level | Below 55 dB | Below 55 dB |
Shelves | Anti-fall, 4 Slide unit | 4 Slide unit |
Unit Weight | 170 kg | 170 kg |
Power Consumption | 70 W | 70 W |
Lock System | Mortise | Mortise |
Power | 220 V / 60 Hz | 220 V / 60 Hz |
Option | - |
Features
Fully-enclosed / self-circulating structure prevents air leakage from the inside of the reagent cabinet
- A contaminated air flowing into the reagent cabinet, over-saturate the filter and reduce filter life.
- A contaminated filters can be a source of pollution, emitting odor and harmful gas.
- A self-circulation avoid loss of cooling and heating energy
Fluid dynamics design Creation of ideal filter efficiency via pressure diffrential pressure
- The reagent cabinet is designed ti have negatice pressure of-0.3 hpa by differential pressure
- The air inside the cabinet is not vented to the outside
- The flow of velocity at the bottom of cabinet is designed to be 0.5 m/s to prevent the back-flow of odor and harmful gas molecule
KASSIA module (Ion-cluster)
Removes odor and harmful gas with ion cluster Ion cluster is a group of 10~60 oxygen molecules that directly oxidize various radicals including oxygen anions, cations and OH and odor substance eliminate pollutants.
- The KASSIA module equipped with semi-permanent ion cluster removes odor and harmful gas.
- Removes over 95 % of odor and harmful gas.
CxHy + (x+y/4)O2
xCO2 + (y/2)H2O
scroll left and right >
NAME | Chemical formula | Elimination reaction | |
---|---|---|---|
Toluene | C₇H₈ |
C₇H₈ + 9O₂
CO₂ + H₂O
|
|
Benzene | C₆H₆ |
2C₆H₆ + 15O₂
12CO₂ + 6H₂O
|
|
Methane | CH₄ |
CH₄ + 2O₂
CO₂ + 4H₂O
|
|
Ammonia | NH₃ |
4NH₃ + 3O₂
2N₂ + 6H₂O
|
|
Acetaldehyde | C₂H₄O |
2C₂H₄O + 5O₂
4CO₂ + 4H₂O
|
|
Formaldehyde | CH₂O |
CH₂ + O₂
CO₂ + H₂O
|
|
Ethylene | C₂H₄ |
C₂H₄ + 3O₂
2CO₂ + 2H₂O
|
7-inch color touch display
- Temperature, humidity, VOCs concentration display
- gas concentration and humidity live graph display
- Display of KASSIA Module and filter inspection interval graph (notification)
Slide-out shelves
- Height adjustable
- Convenient reagent storage with sliding shelves
Magnetic lock
- Touch display password
- Adhesive weight : 270kgs
Auto Caster
- Balance and height adjuster
- Wheel locking function
- Anti-fall system
Materials
- PP(Polypropylene)
Tempered glass
- Heat and impact resistance
- Convenient observation of the reagent cabinet
Exclusive filter for strong acid/alkali
SNPD Series
Fully-enclosed·Self-circulating
1 Door / 2 Door
Fully-enclosed·Self-circulating
acid resistance reagent cabinet
1 Door / 2 Door
Patent no. 10-0776563(Fully-enclosed·Self-circulating reagent safety cabinet)
Purpose of use
Technical Specifications
scroll left and right >
※ Specification are subject to change without notice for improved performance
Standard / Model | ZEO-SN142PD | ZEO-SN141PD | ZEO-SN140PD | ZEO-SN152PD | ZEO-SN151PD | ZEO-SN40PD |
---|---|---|---|---|---|---|
External Size(WxDxH)mm | 700 x 565 x 1,800 | 700 x 565 x 1,200 | 670 x 660 x 600 | 700 x 565 x 1,800 | 700 x 565 x 1,200 | 670 x 660 x 600 |
Interior Size(WxDxH)mm | Top 600 x 450 x 645 / 174 L Bottom 600 x 450 x 775 / 221 L |
600 x 450 x 920 / 250 L | 580 x 450 x 500 | Top 60 0 x 450 x 645 / 174 L Bottom 600 x 450 x 775 / 221 L |
600 x 450 x 920 / 250 L | 580 x 450 x 500 |
Max, load per shelf | 30 Kg | 30 Kg | 30 Kg | 30 Kg | 30 Kg | 30 Kg |
Noise Level | Below 55 dB | Below 55 dB | Below 55 dB | Below 55 dB | Below 55 dB | Below 55 dB |
Shelves | Anti-fall 4 Slide unit | Anti-fall 3 Slide unit | Anti-fall 2 Slide unit | 4 Slide unit | 3 Slide unit | 2 Slide unit |
Unit Weight | 150 kg | 110 kg | 45 kg | 150 kg | 110 kg | 45 kg |
Power Consumption | 60 W | 60 W | 60 W | 60 W | 60 W | 60 W |
Lock System | Mortise | Mortise | Mortise | Mortise | Mortise | Mortise |
Power | 220 V / 60 Hz | 220 V / 60 Hz | 220 V / 60 Hz | 220 V / 60 Hz | 220 V / 60 Hz | 220 V / 60 Hz |
Option | - | - | - |
Features
Fully-enclosed / self-circulating structure prevents air leakage from the inside of the reagent cabinet
- A contaminated air flowing into the reagent cabinet, over-saturate the filter and reduce filter life.
- A contaminated filters can be a source of pollution, emitting odor and harmful gas.
- A self-circulation avoid loss of cooling and heating energy
Fluid dynamics design Creation of ideal filter efficiency via pressure diffrential pressure
- The reagent cabinet is designed ti have negatice pressure of-0.3 hpa by differential pressure
- The air inside the cabinet is not vented to the outside
- The flow of velocity at the bottom of cabinet is designed to be 0.5 m/s to prevent the back-flow of odor and harmful gas molecule
KASSIA module (Ion-cluster)
Removes odor and harmful gas with ion cluster Ion cluster is a group of 10~60 oxygen molecules that directly oxidize various radicals including oxygen anions, cations and OH and odor substance eliminate pollutants.
- The KASSIA module equipped with semi-permanent ion cluster removes odor and harmful gas.
- Removes over 95 % of odor and harmful gas.
CxHy + (x+y/4)O2
xCO2 + (y/2)H2O
scroll left and right >
NAME | Chemical formula | Elimination reaction | |
---|---|---|---|
Toluene | C₇H₈ |
C₇H₈ + 9O₂
CO₂ + H₂O
|
|
Benzene | C₆H₆ |
2C₆H₆ + 15O₂
12CO₂ + 6H₂O
|
|
Methane | CH₄ |
CH₄ + 2O₂
CO₂ + 4H₂O
|
|
Ammonia | NH₃ |
4NH₃ + 3O₂
2N₂ + 6H₂O
|
|
Acetaldehyde | C₂H₄O |
2C₂H₄O + 5O₂
4CO₂ + 4H₂O
|
|
Formaldehyde | CH₂O |
CH₂ + O₂
CO₂ + H₂O
|
|
Ethylene | C₂H₄ |
C₂H₄ + 3O₂
2CO₂ + 2H₂O
|
4.3 inch color touch screen display (Entry type)
- Temperature, humidity, VOCs concentration display
- KASSIA Module and filter replacement interval notification
Slide-out shelves
- Height adjustable
- Convenient reagent storage with sliding shelves
Magnetic lock
- Touch display password (ZEO-SN142P, ZEO-SN142PD, ZEO-SN141PD)
- Handle key locking system (SN142PD / SN141PD / SD142PF / SN142PC)
Auto Caster
- Balance and height adjuster
- Wheel locking function
- Anti-fall system
- SN142PD / SN141PD만 해당
Materials
- PP(Polypropylene)
Tempered glass
- Heat and impact resistance
- Convenient observation of the reagent cabinet
Exclusive filter for strong acid/alkali
SDPF / SDP Series
Fully-enclosed·Self-ventilating
2 Door
Fully-enclosed·Self-ventilating
acid resistance reagent cabinet
2 Door
Purpose of use
Technical Specifications
scroll left and right >
※ Specification are subject to change without notice for improved performance
Standard / Model | Slef-ventilation cabinet | Central air-conditioning | ||
---|---|---|---|---|
ZEO-SD142PFC | ZEO-SD152PF | ZEO-SD142PC | ZEO-SD152P | |
External Size(WxDxH)mm | 700 x 565 x 1,800 | 700 x 565 x 1,800 | 700 x 565 x 1,800 | 700 x 565 x 1,800 |
Interior Size(WxDxH)mm | Top 600 x 450 x 645 / 174 L Bottom 600 x 450 x 775 / 221 L |
Top 600 x 450 x 645 / 174 L Bottom 600 x 450 x 775 / 221 L |
Top 600 x 450 x 645 / 174 L Bottom 600 x 450 x 775 / 221 L |
Top 600 x 450 x 645 / 174 L Bottom 600 x 450 x 775 / 221 L |
Max, load per shelf | 30 Kg | 30 Kg | 30 Kg | 30 Kg |
Noise Level | Below 55 dB | Below 55 dB | - | - |
Shelves | Anti-fall 4 Slide unit | 4 Slide unit | Anti-fall 4 Slide unit | 4 Slide unit |
Unit Weight | 150 kg | 150 kg | 150 kg | 150 kg |
Power Consumption | 60 W | 60 W | - | - |
Lock System | Mortise | Mortise | Key-locking system | Key-locking system |
Power | 220 V / 60 Hz | 220 V / 60 Hz | - | - |
Option | - | - |
Features
Harmful gas flow · fluid dynamics inside the cabinet
- Built-in exhaust fan inside of the cabinet release odor and harmful gas.
- Ventilation distance up to 10 m. (would not work if longer than 10 m)
- Connectable to various duct material.
Harmful gas flow
- Harmful gas is released to the outside by a connected fan.
4.3 inch color touch screen display (Entry type)
- Temperature, humidity, VOCs concentration display
- KASSIA Module and filter replacement interval notification
Slide-out shelves
- Height adjustable
- Convenient reagent storage with sliding shelves
Magnetic lock
- Handle key locking system (SN142PD / SN141PD / SD142PF / SN142PC)
Auto Caster
- Balance and height adjuster
- Wheel locking function
- Anti-fall system
Materials
- PP(Polypropylene)
Tempered glass
- Heat and impact resistance
- Convenient observation of the reagent cabinet